- Sep 12, 2024
-
-
Schabbauer, Johannes authored
-
- Apr 15, 2024
-
-
Schabbauer, Johannes authored
This reverts commit 4a8e3d1a.
-
- Apr 10, 2024
-
-
Schabbauer, Johannes authored
-
- Apr 08, 2024
-
-
Schabbauer, Johannes authored
-
- Feb 23, 2023
-
-
Schabbauer, Johannes authored
-
- Jan 23, 2023
-
-
Schabbauer, Johannes authored
-
- Jan 02, 2023
-
-
Schabbauer, Johannes authored
In BLACS Tab, do not query Worker for all cases, e.g. transition to manual is not required. Added updateing smart_cache in get_remote_values, such that the Worker is aware of changes since the last shot.
-
Schabbauer, Johannes authored
-
- Dec 28, 2022
-
-
Schabbauer, Johannes authored
-
- Dec 09, 2022
-
-
Schabbauer, Johannes authored
This will make the changes easier, in case the repository is named differently. Then one only needs to change the path in register_classes.py.
-
- Nov 24, 2022
-
-
Schabbauer, Johannes authored
-
Schabbauer, Johannes authored
-
- Nov 23, 2022
-
-
Schabbauer, Johannes authored
-
- Nov 21, 2022
-
-
Schabbauer, Johannes authored
-
- Nov 11, 2022
-
-
Schabbauer, Johannes authored
Now the gain of the input set for a PID is considered, such that the set value is the physical voltage that goes into the ADwin. For that I also changed how we keep track of the AIn of PID channel index for the module arrays (moved storage from Attributes in devices to connection_table_properties).
-
- Nov 10, 2022
-
-
Schabbauer, Johannes authored
-
Schabbauer, Johannes authored
-
- Nov 08, 2022
-
-
Schabbauer, Johannes authored
-
Schabbauer, Johannes authored
-
- Nov 01, 2022
-
-
Schabbauer, Johannes authored
-
- Oct 31, 2022
-
-
Schabbauer, Johannes authored
-
- Oct 25, 2022
-
-
Schabbauer, Johannes authored
-
Schabbauer, Johannes authored
-
- Oct 20, 2022
-
-
Schabbauer, Johannes authored
-
Schabbauer, Johannes authored
-
- Oct 14, 2022
-
-
Schabbauer, Johannes authored
Because the TiCo is started later than the Adwin main process, an error is raised if we want to change the output too early again after t=0
-
- Oct 10, 2022
-
-
Schabbauer, Johannes authored
-
- Oct 06, 2022
-
-
Schabbauer, Johannes authored
-
- Oct 04, 2022
-
-
Schabbauer, Johannes authored
-
- Oct 03, 2022
-
-
Schabbauer, Johannes authored
-
Schabbauer, Johannes authored
-
- Sep 30, 2022
-
-
Schabbauer, Johannes authored
-
Schabbauer, Johannes authored
-
Holten, Marvin authored
Implemented reading of analog ins channels to labscript code
-
Holten, Marvin authored
awdawd
-
Schabbauer, Johannes authored
-
- Sep 29, 2022
-
-
Schabbauer, Johannes authored
-
Schabbauer, Johannes authored
Change TiCo rate to 50MHz, collect analog outputs not via PseudoClock but directly from outputs (such that we can use different rates for ramps in the same clockline).
-
- Sep 28, 2022
-
-
Schabbauer, Johannes authored
-
- Sep 27, 2022
-
-
Schabbauer, Johannes authored
-